Pleated Filter Cartridge Cleaning And Wetting
Cleaning and wetting before use
1. Purpose
- To make the filter cartridges more easily and more completely wet.
- Ensure the accuracy of bubble point test.
- To ensure the cleanliness of the filter cartridges.
2. Matters needing attention
- The way of soaking is not recommended.
- It is required to wash rapidly with high flow and pressure.
- The flushing pressure difference shall be kept above 2 bar.
Cleaning and wetting methods
1. Hydrophobic membrane filtration
The hydrophobic membrane filter cartridges is wetted with a 60% isopropanol aqueous solution, and the wetting process is the same as that of the hydrophilic membrane filter cartridges.
2. Hydrophilic membrane filter cartridge
- Prepare filter components: filter, filter cartridge, pressure gauge, combination joint, water pump, pipe fittings.
- Add 10L of pure water to the assembled system and check for leaks in the system.
- Turn on the power switch of the water pump, and fully open the valve, and quickly flush for 5 to 10 seconds. The pressure of the pressure gauge controlled by the valve is adjusted to approximately P1=3±0.2bar.
- It is recommended that the flow rate is greater than 15L/min per 10", and the wet filter cartridge is rinsed for about 20 minutes.